SALUKI S3532B 7.5GHz Spectrum Analyzer
S3532 series spectrum analyzer covers a frequency range up to 7.5GHz. It provides a good performance with a low cost. S3532is a good choice for RF product manufacturing and maintenance. S3532 has rich measurement functions, including spectrum analysis, network measurement, field strength measurement, channel scanning, analog demodulation, and template alarm settings. Standard tracking source is provided for test need stimulus signal. It also provides telecommunication ports such as USB and LAN for remote data collection and remote control. Using the standard SCPI command set, user can quickly set up and upgrade an integrated test system for measurement. S3532 series handheld spectrum analyzer has compact structure and a good performance. S3532 can be used in aerospace, microwave communication, satellite navigation, radar monitoring, electronic detection and countermeasures, precision guidance and other fields.
Features
- Frequency range: 9kHz – 3.6GHz / 7.5GHz
- Resolution bandwidth: 1Hz -3MHz
- Sensitive, standard pre-amplifier, best DANL < -160dBm
- Multi-window, multi-trace, clear display
- Dual signal source (tracking source and normal source)
- Standard LAN and USB interface, support SCPI
- Standard AM, FM demodulation functions
- Standard FFT 1Hz resolution bandwidth function
- Standard 3.2GHz / 3.6GHz tracking source function
- Support field strength measurement, frequency discrimination test, Pass-fail, S11 and S21, channel measurement, etc. functions
Specifications
Model | S3532B | ||
Frequency |
|||
Frequency Range | 9kHz – 7.5GHz | ||
Resolution | 1Hz | ||
Frequency Readout Accuracy | ± (frequency indication × frequency reference+1% × span+10% × RBW+0.5 × [span/(number of sweep points-1)]+1Hz) | ||
Aging Rate | ±1ppm/year | ||
Temperature Stability | ±0.5ppm (15°C to 35°C) | ||
Amplitude |
|||
Measurement Range (fc ≥10MHz) | DANL to +20dBm | ||
Maximum Safe Input Level | +23dBm | ||
Maximum DC Voltage | 50V DC | ||
Input Attenuator Range | 0 – 30dB, Steps of 3dB | ||
Test Port VSWR | 9kHz – 3.4GHz: < 2.0:1 3.4GHz – 7.5GHz: < 2.5:1 |
||
Reference Level Range | -80dBm to +30dBm, step in 1dB | ||
1dB compression | +10dBm | ||
Amplitude Accuracy (20°C to 30°C) | |||
Comprehensive Amplitude Accuracy (90%) | Input range: 0dBm to -50dBm, ±1.5dB | ||
Input / Output |
|||
RF Input/Output | Type -N female (50Ω) | ||
USB | USB 1.1 B, USB 2.0 A | ||
LAN | 10/100 Base-T, RJ-45 Connectivity | ||
AF Output | 3.5mm mini jack for headphones | ||
Reference Input/Output | 10MHz: Input level 0dBm to +10dBm | ||
BNC female: Output level 0dBm ±2dB | |||
Trig. Input | BNC Female | 5V TTL (±10V, 100mA maximum) | |
VGA | 800×480, 60Hz; 15 D-SUB pin (f) | ||
RS232 | 9 D-SUB pin (M) | ||
RBW |
|||
Range | 1Hz – 500kHz (in 1 to 10 step), 1MHz, 3MHz | ||
Resolution Filter Shape Factor (60dB/3dB) | <5:1 (Typ.) | ||
Accuracy | <5% (Typ.) | ||
Video Bandwidth (VBW) | 10Hz – 3MHz | ||
DANL |
|||
Frequency | 100kHz – 1MHz 1MHz – 10MHz 10MHz – 2GHz 2GHz – 3.4GHz 3.4GHz – 5GHz 5GHz – 7.5GHz |
||
Preamp Off | <-95dBm-3×(f/100kHz)dB <-125dBm <-133dBm <-130dBm <-133dBm <-127dBm |
||
Preamp On | <-110dBm-3×(f/100kHz)dB <-140dBm <-148dBm <-143dBm <-145dBm <-138dBm |
||
Phase Noise |
|||
SSB phase noise (RBW=1kHz, Sample detector, Trace average ≥10) | |||
CF=500MHz | Carrier offset 30kHz | -80dBc/Hz | |
Carrier offset 100kHz | -90dBc/Hz | ||
Carrier offset 1MHz | -110dBc/Hz | ||
Sweep Time |
|||
Full Span | 3ms – 3000s | ||
Zero Span | 1ms – 3000s | ||
Sweep Mode | Continuous, Single | ||
Best Sweep Time (Full Span) | < 100ms | ||
Spurious Response |
|||
TOI (>30MHz) | +13dBm | ||
SHI (>10MHz) | +40dBm | ||
Input Related Spurious (>10MHz) | <-60dBc | ||
Inherent Residual Response (>10MHz) | <-85dBm | ||
Tracking Generator |
|||
Frequency Range | 100kHz – 3.2GHz | ||
Output Level | -30dBm to 0dBm Stepped by 1 dB | ||
Output Flatness | ±3dB | ||
General |
|||
Display | 8.4 inch TFT LCD | ||
Detector | Sample, Peak, Negative Peak, Normal | ||
Marker Counter Resolution | 1Hz, 10Hz, 100Hz, 1kHz | ||
Limit Line | Available | ||
Dimension | 390 (H) x 182 (W) x 230 (D) mm | ||
Weight | 6.5kg | ||
Operating Temperature | 0°C to 40°C | ||
Storage Temperature | -20°C to +70°C | ||
Power | Input Voltage | 100V – 240V AC | |
Input Frequency | 40Hz – 60Hz | ||
Consumption | Max. 30W | ||
Standard Accessories | Main Unit Power Cord CD |
||
Datasheet | S3532-Series-Spectrum-Analyzer-Datasheet |